What CH67 means

The outdoor fan blows air across the condenser coil to dissipate heat from the refrigerant. CH67 appears when the fan motor is not spinning — either because it is jammed, the motor has failed, or the motor is not receiving power from the outdoor PCB.

LG's official guidance advises checking for debris or snow buildup around the fan first.

Do not run the AC with CH67 showing. Without the outdoor fan, the condenser pressure spikes rapidly, potentially damaging the compressor.

How to fix it

  1. Power off at the breaker.
  2. Inspect the fan visually. Look through the top grille of the outdoor unit — is there debris, a bird nest, ice, or snow blocking the blade?
  3. Clear any obstruction. Remove debris carefully. If the fan is frozen in winter, let it defrost naturally — do not force it.
  4. Try spinning the blade by hand (with power off). It should turn smoothly with slight resistance. If it feels stiff or stuck, the motor bearings may be seized.
  5. Check the motor connector inside the outdoor unit's electrical compartment (qualified personnel only). Reseat the plug.
  6. Replace the fan motor if it is seized or does not start when powered. Match the motor to your LG model number.